The FSM Foam Structure Module for the DFA100 captures the bubble size and size distribution of foam using intelligent video image analysis. The results help you to produce foam with the shape you want it to have. They also show the decay of long-lasting foam, long before it actually collapses, thus supporting you in optimizing foam stability.
DFA100FSM
Time-dependent analysis of bubble size in liquid foams
Description
SPECIFICATIONS
SPECIFICATIONS
Software
| Software type | ADVANCE |
|---|---|
| Software languages | Chinese (simplified), English, French, German, Japanese, Korean, Portuguese, Russian, Spanish |
| Software modules | Foam analysis (recommended)
Remote Control API (optional) |
Measurement specifications
| Analyzed foam characteristic | foamability and foam stability foam structure: homogeneity, stability and aging |
|---|---|
| Results | foam height liquid height total height foam capacity maximum foam density expansion rate foam half life time drainage half life time sample temperature mean bubble area bubble count per mm² standard deviation of mean bubble area bubble size distribution bubble count half life Sauter mean radius initial foam structure final foam structure |
Sample dimensions
| Min. recommended sample volume | 50 mL with 40 mm diameter column 20 mL with 20 mm diameter column |
|---|
Instrument dimensions
| Footprint | 245 mm × 275 mm (W × D) |
|---|---|
| Height | 460 mm |
| Weight (without accessories) | 13 kg |
Environment
| Operating temperature | 15 to 30 °C |
|---|---|
| Humidity | without condensation |
Interfaces
| PC | 1× USB 2.0 1× USB 3.0 |
|---|
Power supply
| Voltage | 100 to 240 V |
|---|---|
| Power consumption | 30 W |
| Frequency | 50 to 60 Hz |
Temperature measurement
| Sensor | PT100 |
|---|---|
| Range | 4 to 90 °C |
| Resolution | 0.1 °C |
| Precision | ±0.1 °C |
| Accuracy | 1/3 DIN B (±0.1 °C at 0 °C / ±0.8 °C at 400 °C) |
| Locations | inside sample liquid |
| External sensor | optional |
Temperature control
| Type of temperature control | optional: double-walled glass column |
|---|---|
| Range of temperature control | 10 to 60 °C (additional thermostat needed) |
Accessories
| Glass columns | 40 mm diameter, temperature control option |
|---|---|
| Filter plates for sparging | diameter: 30 mm |
| Filter plate porosities | G1: nominal maximum pore size: 100 to 160 μm G2: nominal maximum pore size: 40 to 100 μm G3: nominal maximum pore size: 16 to 40 μm G4: nominal maximum pore size: 10 to 16 μm |
| Material of columns and frits | borosilicate glass (norm: ISO 4793) |
| Material of sealings | silicone and FKM |
Camera system
| Diameter of minimum detectable bubble | 50 µm |
|---|---|
| Mean field of view size | position 1: 285 mm2 position 2: 140 mm2 position 3: 85 mm2 |
| Focus | manual |
Camera system (standard)
| Connection | USB 3.0 |
|---|---|
| Performance | 2 fps at 1280 × 1024 px |
Illumination
| Types | LED |
|---|---|
| Wave length, dominant (height detection) | 469 nm (optional IR: 850 nm) |
| Wave length, dominant (structure detection) | 633 nm |
Electrodes
| Material | – |
|---|---|
| Highest sensor position | – |
| Measured entity | – |
| Theoretical measurement range | – |
Operating system
| Internal gas flow rate | 0.2 to 1 L/min |
|---|---|
| External gas flow rate | 0.05 to 1 L/min |
| Approved gases | air nitrogen carbon dioxide |
| Approved pressure | 5 ± 0.5 bar |
| Approved temperature | 4 to 90 °C |
| Stirring speed | up to 8000 rpm |
Line sensor
| Sensor resolution | 1728×1px |
|---|---|
| Spatial resolution | 200 dpi | 0.125 mm |
| Temporal resolution | 20 fps |
| Scanning length | 216 mm |
Shipping & Delivery
Category: Kruss